MM0021: Chunk Errors Occur on Nexsan Devices

Symptom

Chunk errors occur on Nexsan devices with the following errors:

Error Code 40:91:
 Failed to Copy or verify Chunk [] in media [], Storage Policy [], Copy [], Host [], Path [], File Number [], Backup Jobs [].\].Data read from media appears to be corrupted. Data read from media appears to be corrupted.
Error Code 62:469:
 Data read from media appears to be corrupted.

Log files might include entries similar to the following:

AuxCopy.log located on the corresponding MediaAgent:

[F:\MAG11-F\BASE-F\CV_MAGNETIC\V_6561581\CHUNK_5847058\CHUNK_META_DATA_5847058] file 14490301-16560393 [DM_BASE ] DataMoverSingleInstancer::OpenChunkSpecific: Not honoring readless mode because this job type is [13]. Dest Copy Id [0] 14490301-16560393 [DM_BASE ] Readless mode [false] CCVAPipelayer::SetEncryptProps() - Entered CCVAPipelayer::SendCommandToDSBackup() - Sent Command 156 to MediaAgent, Waiting for Response... [PIPELAYER ] Tail response = Get PL_SET_ENC_PROPS Message Status = 0 dwCode = 0 MsgType = 16 MsgSubType = 156 EventError = 0 Successfully opened the archive files on the media...going to read data. ###### [ NULL] invalid tag header 14490301-16560393 [DM_BASE ] **ERROR** DataMoverSingleInstancer::ReadTagHeader: Failed to convert the tag header to Host byte order. Tag header got =

JobManager.log located on the corresponding MediaAgent:

Scheduler Set pending cause [Failed to Copy or verify Chunk [5847058] in media [CV_MAGNETIC], Storage Policy [...], Copy [1:Primary Disk], Host [...], Path [F:\MAG11-F\BASE-F\CV_MAGNETIC\V_6561581], File Number [121], Backup Jobs [ ].Data read from media appears to be corrupted.aData read from media appears to be corrupted.a]::Client [...] Application [AuxCopy] Message Id [671088731] RCID [14490301] ReservationId [0]. Level [0] flags [0] id [0] overwrite [0] append [1] CustId[1040187861].

Resolution

Older Nexsan firmware must be updated. Use the appropriate version based on your storage device type.

  • For SATABeast 2.5, use firmware version Pp70 or later.

  • For SATABeast 2, use firmware version Nj67 or later.

  • For other devices, contact Nexsan.

A list of the latest firmware release is available at https://helper.nexsansupport.com/.

Page contents

×

Loading...