Applies to: Dell EMC VNX and Dell EMC CLARiiON
For IntelliSnap backups from Commvault software, add the Dell EMC VNX / CLARiiON storage array and its configuration information to the CommServe database.
Before You Begin
Ensure that the client and proxy computers have access to the storage array.
Procedure
- 
On the ribbon in the CommCell Console, click the Storage tab, and then click Array Management. The Array Management dialog box appears. 
- 
Click Add. The Array Properties dialog box appears. 
- 
On the General tab, specify the following information: - 
From the Snap Vendor list, select Dell EMC VNX / CLARiiON. 
- 
In the Name box, enter the serial number of the array. 
- 
In the Control Host box, enter the serial number of the array. 
- 
In the Credentials area, click Change. The Enter the User Name and Password dialog box appears. 
- 
Type the credentials of a user who has the rights to access the array, and then click OK. 
 
- 
- 
To configure additional MediaAgents to perform operations on the storage array, click the Array Access Nodes tab, and then select configuration options. For more information, see Configuring Array Access Nodes. 
- 
On the Snap Configuration tab, configure the snapshot configuration properties for your environment or use the default values. For more information, see Snap Configuration. 
- 
Click OK.