To use the metrocluster configuration, you need to configure both storage arrays in Arrays page, and for the NetApp cluster, you also need to configure the disaster recovery (DR) Partner snapshot configuration property.
Before You Begin
-
If you are using OnCommand Unified Manager (OCUM), ensure that the vServer has a storage virtual machine (SVM) association in OCUM. The source SVM and the DR SVM must have an SVM association to the target SVM.
-
For NDMP backups from the cluster client, add the NAS client in Arrays page. For more information, see Adding a Storage Array to the CommServe Database.
-
After cluster switchover and switchback, if you try to suspend and resume NDMP jobs, the operation fails. You need to resubmit the backup job.
-
You cannot use a MetroCluster array as target for replication.
Procedure
-
From the Command Center navigation pane, go to Manage > Infrastructure.
The Infrastructure page appears.
-
Click Arrays.
-
On the Arrays page, in the Name column, select NetApp array.
The Overview page of the array appears.
-
Under Configuration tab, in the Snap configurations tile, click Edit
.The Edit configuration dialog box appears.
-
In the DR Partner box, type the name of the DR partner.
-
Click Submit.