Commvault Systems, Inc. tests major versions and some minor versions of firmware, so the best practice is to use the supported versions listed in this topic. If you encounter a problem with a minor version during an IntelliSnap operation, contact Commvault Systems, Inc..
IntelliSnap backup is designed to work in conjunction with the following storage arrays/cloud platforms that provide snapshot functionality for data protection operations:
|
Vendor |
Snapshot |
Version or Firmware |
Licensing |
Software |
Protocol |
Notes/Caveats |
|---|---|---|---|---|---|---|
|
Amazon Web Services |
EBS Snapshot |
None |
None |
None |
None |
|
|
Amazon FSx for NetApp ONTAP |
Snapshot |
ONTAP 9.16.1, 9.15.1, 9.14.1, 9.13.1, 9.12.1, 9.11.1 |
|
|
||
|
Azure NetApp Files |
Snapshot |
SAP HANA requires the NFSv4.1 protocol according to Microsoft and SAP requirements. |
||||
|
Dell EMC Isilon/PowerScale |
Snapshot |
OneFS 9.10 through 7.0 |
SnapshotIQ License |
|
|
|
|
Dell PowerStore |
Snapshot |
|
None |
None |
|
None |
|
Dell PowerFlex |
Snapshot |
|
None |
ScaleIO Data Client (SDC) drivers on the client computer and proxy computer where snapshots are mounted. |
ETH/IB |
|
|
Dell EMC Storage Center (DSM) |
Snapshot using DSM |
|
|
Dell EMC Storage Manager: Dell EMC Storage Manager client, Dell EMC Storage Manager data collector, and Dell EMC Storage Manager Server |
|
|
|
Dell EMC Unity |
Snapshot |
Firmware: 5.5, 5.4, 5.3.1, 5.2.0, 5.1.2.0.5.007, 5.0.6.0.5.008, 5.0.3, 5.0.2.0.5.009, 4.5.1, 4.4.0, 4.3.1, 4.2.1, 4.1.2, 4.1.0 Models:
|
Enterprise license |
|
|
|
|
Dell EMC PowerMAX VMAX All Flash/ VMAX3 |
Dell EMC TimeFinder SnapVX Dell EMC TimeFinder VP Snap Dell EMC TimeFinder Clone |
PowerMAX VMAX All Flash VMAX3 |
TimeFinder SnapVX TimeFinder VP Snap TimeFinder Clone Solutions Enabler Licensing |
|
|
|
|
Dell EMC VMAX |
Dell EMC TimeFinder VP Snap Dell EMC TimeFinder Clone Dell EMC TimeFinder Snap Dell EMC TimeFinder BCV |
VMAX |
TimeFinder VP Snap TimeFinder Clone TimeFinder Snap TimeFinder Mirror Solutions Enabler Licensing |
|
|
|
|
Dell EMC Symmetrix |
Dell EMC TimeFinder Clone Dell EMC TimeFinder Snap Dell EMC TimeFinder BCV |
DMX3 and later |
Licenses for: TimeFinder Clone TimeFinder Snap TimeFinder Mirror Solutions Enabler Licensing |
Solutions Enabler 6.4 or later on client and proxy computers |
|
|
|
Dell EMC VPLEX |
Snapshot Clone |
GeoSynchrony® 6.2, 6.1.0.1, 6.0 Metro node 8.0, 7.1 |
On the client or on the Remote Snap MA: Python 3.11.4, 3.9.11, 3.9.6, 3.9.2, 3.8.1, 3.6.4, 2.7, 2.6 On UNIX: openssl-devel package |
Fibre Channel |
||
|
Dell EMC XtremIO |
Snapshot |
|
|
|||
|
Google Cloud |
Snapshot |
None |
None |
None |
None |
|
|
Hitachi NAS |
Snapshot |
15.1, 14.9, 14.8, 14.7, 14.6, 14.5, 14.4, 14.3, 14.2, 13.9, 13.8, 13.7, 13.6, 13.5, 13.4, 13.3, 13.2, 13.0, 12.7 REST API Version 7.0, 4.0 |
CIFS, NFS |
For Hitachi NAS versions 13.2.x and later, use the in-built metro server. For Hitachi NAS earlier versions than 13.2.x , install an external metro server version 4.0. |
|
|
|
Hitachi Vantara VSP using CCI Engine |
ShadowImage (SI) Thin Image (TI) |
For information on HTI and HTIA snapshot support, see system requirements. |
|
RAID Manager (01-29-03/05 and later) installed on client and proxy. For VSM, use RAID Manager (01-32-03/01 and later) installed on client and proxy. |
Fibre Channel |
|
|
HPE Alletra 5000 Series |
Snap and Replicate |
|
Included |
None |
|
|
|
HPE Alletra 6000 Series |
Snap and Replicate |
|
Included |
None |
|
|
|
HPE Alletra 9000 Series |
Snapshot and Clone |
*If you have upgraded to HPE Alletra 9000 Series 9.6.1 version, ensure to set the SMIS Server Port to 5989 and enable Use secure connection to SMIS Server snapshot configurations. For more information, see snapshot configuration properties. |
Virtual Copy |
None |
|
|
|
HPE GreenLake for Block, powered by Alletra MP |
Snapshot and Clone |
*Supports only Linux and VMWare systems with iSCSI protocol. **Replication for this array version is not supported by Commvault due to the behavioral changes done by HPE in virtual volume sets and RCG. |
Virtual Copy |
None |
|
|
|
HPE Primera |
Snapshot and Clone |
*If you have upgraded to HPE Primera 4.6.1 version, ensure to set the SMIS Server Port to 5989 and enable Use secure connection to SMIS Server snapshot configurations. For more information, see snapshot configuration properties. |
Virtual Copy |
None |
|
|
|
HPE 3PAR StoreServ |
Snapshot and Clone |
|
Virtual Copy Thin Provisioning (4096G) license is required when Thin Provisioning is enabled for cloning |
None |
|
|
|
HPE Nimble Storage |
Snap and Replicate |
6.1.x, 6.0.x, 5.2.x, 5.1.x, 5.0.x, 4.x, 3.x Nimble CS-Series, AF-Series, and HF-Series |
Included |
None |
|
|
|
HPE Nimble dHCI |
Snap and Replicate |
5.2.x Nimble AF-Series, and HF-Series |
Included |
None |
|
|
|
Microsoft Azure |
Snapshot |
None |
None |
None |
None |
|
|
NetApp |
Snapshot |
For 7-Mode: Product
For Cluster-Mode: Product
|
|
|
|
|
|
Pure |
Snapshot |
|
None |
None |
|
|
|
VAST Data Platform |
Snapshot |
5.0.0.x |
None |
None |
|
|
|
Western Digital IntelliFlash |
Snapshot |
|
None |
None |
|
*Supported through Field Certification. Contact your Software Provider or Professional Services to see if the specific FCoE can be supported.
**Replication for this version of array is pending validation by Commvault.
Notes
-
Do not install the Commvault Cloud software on the same volume that you are protecting with the IntelliSnap backup feature.
-
Subclients must contain LUNs (Logical Unit Number) from the same storage array. You can configure subclients with LUNs from multiple storage arrays of the same vendor for NetApp, Pure Storage FlashArray, and Hitachi Vantara VSP running the Hitachi Vantara CCI engine. Do not use this configuration on other storage vendors.
-
NetApp storage arrays support LUNs from multiple NetApp storage arrays, if the subclients are on the same filer operating system. For example, LUNs from 7-Mode and LUNs from Cluster-Mode cannot be part of the same subclient.
-
Commvault Cloud software supports IntelliSnap backups of subclients that have LUNs from multiple Hitachi Vantara VSP storage arrays that use Hitachi Vantara CCI engines.
-
Most capabilities of Data ONTAP 7-Mode apply to Cluster-Mode, but cascaded replication of primary to snapvault to snapmirror on a single policy is not supported.
-
Dynamic Disks on Window Operating Systems are not supported.
-
When performing IntelliSnap backup for a Windows MSCS Cluster, a separate proxy server (external to the cluster nodes) must be used for mount, backup, and restore operations as disk signature conflicts might occur if these operations are performed from one of the servers in the cluster.
-
Booting from SAN volumes is not supported.
-
The IntelliSnap feature is not supported for VMware data stores created using local disks. The data stores should be created from LUNs.
-
NAS attached tape libraries are not supported for IntelliSnap operations.
-
The backup copy operation is not supported on a client computer that is upgraded to a version higher than its associated MediaAgent. For example, there is no support for backup copy operations if the client runs version 10 and the MediaAgent runs version 11.
-
IntelliSnap backups of Raw Device Map (RDM) disks (passthrough disks for Hyper-V) are supported for all agents, but the Virtual Server Agent only provides support for VMware and Microsoft Hyper-V virtual machines:
-
For VMware, see Include RDMs and Independent Disks in IntelliSnap Backup Operations.
-
Hyper-V backups include passthrough disks if the following conditions are met:
-
The virtual machine has a File System agent or another supported agent installed on it and uses that agent for IntelliSnap backups.
-
The client computer (physical or virtual) is configured to mount snapshots using the iSCSI initiator, or the physical proxy server is configured to mount snapshots over Fibre Channel.
-
The passthrough disk on the virtual machine is attached using a virtual Fibre Channel adapter.
-
-
-
For VMware VMs, the host of the virtual computer must have ESX server version 5.0 or later.
-
RDM disks are not supported by the Hitachi Vantara HDvM engine.
-
Revert operation is not supported for LUNs configured as RDMs for the NetApp storage array.
-
For NetApp arrays and arrays that use the NetApp Snap engine, if you are using AIX, HP-UX, or Solaris clients or access nodes, the following conditions apply:
-
For ONTAP versions earlier than 9.11.1, snapshot and other operations are not supported. However, you can configure and use a Windows or Linux-based remote MediaAgents or proxy access node to perform those operations.
-
For ONTAP versions 9.11.1 or later:
-
Snapshot and other operations are supported only if REST APIs are enabled on the array. For information on enabling REST APIs, see the How to enable REST API based authorization? section on Frequently Asked Questions for the NetApp Storage Array.
-
Configure and use a Windows or Linux-based data path MediaAgents for the storage policy copy to perform snapshot replication.
-
-