Installing the Standby CommServe Host

Install the Commvault software packages on the standby CommServe host. You can also setup more than one standby CommServe hosts, if necessary.

Before You Begin

  • Verify that the prerequisites needed to setup the environment are available before setting up the High Availability CommServe Host feature.

  • Install the Commvault software packages on the production CommServe host.

  • Download the Commvault software installation packages. For more information on how to download software, see Downloading Software and Packages From Cloud Services.

  • Verify and ensure that Two-Factor Authentication is either disabled, or use an account without Two-Factor Authentication to install the standby CommServe host.

    Standby CommServe installation will fail if Two-Factor Authentication is enabled at the CommCell level with Time-based One-Time Password. Instance002 will install successfully, but instance001 will fail as it will try to use the same credentials which is only valid for 1 time. For more information, see the following topics:

Procedure

  1. Log on to the standby CommServe host as an Administrator or as a member of the Administrator group on that computer.

  2. Launch theCommvault software installation package.

    The Download Manager dialog box is displayed.

    embd_Installing the Production CommServe Host procedure (1)

  3. Click Extract.

    The Language Selection page is displayed.

    embd_Installing the Production CommServe Host procedure (26)

  4. Select the language from the Please Choose a Language list, and then proceed to the next page.

    The Welcome page is displayed.

    embd_Installing the Production CommServe Host procedure (27)

  5. Select the I Agree check box, and then proceed to the next page.

    The Choose the Installation Type page is displayed.

    embd_Installing the Production CommServe Host procedure (28)

  6. Click Install packages on this computer, and then proceed to the next page.

    The Select Packages page is displayed.

    embd_Installing the Production CommServe Host procedure (29)

  7. Select the following check boxes, and then proceed to the next page.

    • CommServe check box

    • CommServe Failover check box (Scroll through the list to locate this package.)

      Note

      The CommServe Failover package automatically installs the SQL Server agent and the CommServe Failover packages in a new instance. (No additional user intervention is needed.)

    The Select Hotfix Packages page is displayed.

    embd_Installing the Production CommServe Host procedure (30)

  8. Select the same hotfix option that you selected during the installation of the production CommServe host, and then proceed to the next page.

    If you have not already, make a note of the selected option. It is important to install the same hotfixes for all packages in the production and standby CommServe hosts.

    The Failover Install Option page is displayed.

    embd_Installing the Production CommServe Host procedure (31)

  9. Select This is a standby node, and then proceed to the next page.

    The Installation Path page is displayed.

    embd_Installing the Production CommServe Host procedure (20)

  10. Verify the path (or specify a new path) for the SQL client, and then proceed to the next page.

    Note

    This Installation Path is for the SQL client as the SQL client is installed first on the standby CommServe host.

    The Installation Summary page is displayed.

    embd_Installing the Standby CommServe Host procedure (1)

  11. Verify the list of packages, and then proceed to the next page.

    The software installs the binaries for setting up the SQL client. This process may take a few minutes.

    The Network Configuration page is displayed.

    embd_Installing the Standby CommServe Host procedure (2)

  12. Choose an appropriate option for configuring the firewall in your environment, and then proceed to the next page.

    The Client Computer Information page is displayed.

    embd_Installing the Standby CommServe Host procedure (4)

  13. Type an appropriate name for the standby SQL client, and then proceed to the next page.

    This is the name of the SQL client in the standby CommServe host. Choose a meaningful name to differentiate this entity in the CommCell Console and other disaster-recovery-related interfaces.

    The CommServe Information page is displayed.

    embd_Installing the Production CommServe Host procedure (22)

  14. Type the Fully Qualified Domain Name (FQDN) of the production CommServe host, and then proceed to the next page.

    This is the name that you noted while installing the production CommServe host.

    The Client Certificate page is displayed.

    embd_Installing the Production CommServe Host procedure (23)

  15. If a certificate is available, type the name with the full path to the certificate file and proceed to the next page.

    The CommServe Authentication page is displayed.

    embd_Installing the Production CommServe Host procedure (24)

  16. Type the credentials that must be used to access the production CommServe host, and then proceed to the next page.

    These are the account details that you noted while installing the production CommServe host.

    The software installs the binaries for setting up the SQL client. This process may take a few minutes.

    Note

    This completes the SQL Client installation and the following prompts are displayed for installing the standby CommServe client.

    The Select Hotfix Packages page is displayed.

    embd_Installing the Production CommServe Host procedure (30)

  17. Select the same option that you selected for the Hotfix Packages during the CommServe installation, and then proceed to the next page.

    The software installs the binaries for setting up the standby CommServe host This process may take a few minutes.

    The Installation Path page is displayed.

    embd_Installing the Standby CommServe Host procedure (8)

  18. Verify the path (or specify a new the path) for the standby CommServe server and then proceed to the next page.

    Important

    Note that this Installation Path is for the CommServe server.

    The Client Computer Information page is displayed.

    embd_Installing the Standby CommServe Host procedure (5)

  19. Type an appropriate name for the standby CommServe host.

    This is the name of CommServe client in the standby CommServe host. Choose a meaningful name to differentiate this entity in the CommCell Console and other disaster-recovery-related interfaces.

    The software creates the databases and services. This process may take a few minutes.

    A message similar to the following is displayed:

    embd_Installing the Standby CommServe Host procedure (6)

  20. Click Finish to complete the installation.

Notes

  • To troubleshoot errors that occur before the installation summary page, check the %allusersprofile%\Commvault Systems\Galaxy\LogFiles\Install.log file.

  • If the error occurs after the summary page, then check the installation logs in the software_installation_directory\Log Files folder.

Result

The following components will be available in the Start menu or as shortcuts in the list of Apps.

  • Commvault Command Center

  • Commvault CommCell Console

  • 2 shortcuts to Commvault Process Manager to manage the following entities:

    • CommServe Server - Open the Process Manager > Service tab and you will notice that all the services are not started. (Do not start the services.)

    • SQL Client - Open the Process Manager > Service tab and make sure that the services are started.

What to Do Next

  • Depending on your environment settings and requirements, you may need to perform additional tasks to complete the CommServe installation process. For more information on these tasks, see Post Installation Tasks for the CommServe.

  • If a passphrase key management server is configured in the CommCell environment and the passphrase is exported to the CommServe client, then you must export the passphrase to the SQL clients of all nodes instead of exporting to CommServe client. The export of the passphrase to all clients ensures that the passphrase is available on all the nodes.

  • If an AWS Key Management Service (KMS) Server or a Key Management Interoperability Protocol (KMIP) server is configured in the CommCell environment, then you must copy the certificates to all the nodes under the same path.

  • Enable the CommServe LiveSync feature which facilitates CommServe Recovery Using High Availability CommServe Host. For more information on enabling the LiveSync operation, see Enabling and Disabling CommServe LiveSync.

  • If the failover is setup using a floating CommServe name and if the clients connect to the CommServe using one-way network routes from the client to the CommServe, perform the following steps (one-time operation) to maintain the floating CommServe hostname in the standby CommServe. (These steps are applicable only when the CommServe is in SP18 or below.)

    1. Navigate to the following folder in the active CommServe:

      Program Files\Commvault\ContentStore\Base

    2. Use the following command to set the floating CommServe Hostname in the DB and registry:

      SetPreImagedNames.exe CSNAME -hostname <CS_Floating_Name> <CS_Physical_name> -skipodbc -passiveCS

      For example:

      SetPreImagedNames.exe CSNAME -hostname floatingCS.company.com passiveCS.company.com -skipodbc -passiveCS

Additional Notes

Any additional packages installed on the primary CommServe host, which includes other Commvault packages, or any third-party components, must be manually installed in the standby CommServe host. Also once the LiveSync operation is enabled, the LiveSync process will synchronize the information stored in the CommServe database from the production to the standby CommServe. For example, passwords and Additional Settings stored in the database. Any additional entities, such as third-party packages, scripts, registry keys, certificates, IIS settings, configuration files, etc. must be manually applied before or after failover as needed.