Use the 3PARMigratedLunMap additional setting to identify the correct HPE 3PAR StoreServ/ Primera / HPE Alletra 9000 Series / HPE GreenLake for Block storage array for migrated volumes.
The additional setting creates a migrated LUN mapping that stores the association between the LUN and the storage array to which you migrated the LUN.
Procedure
To the client computer, where the snapshot backup operation runs, add the 3PARMigratedLunMap additional setting as shown in the following table.
For instructions on adding additional settings from the CommCell Console, see Adding or Modifying Additional Settings from the CommCell Console.
|
Property |
Value |
|---|---|
|
Name |
|
|
Category |
iDataAgent |
|
Supported Values |
MAP-String |
where:
Map-String denotes a string that contains the LUN WWN and the storage array ID, separated by the pipeline character.
Example:
For n migrated LUNs:
3PARMigratedLunMap1 :: 50002AC00065146C|2FF70002AC012204
3PARMigratedLunMap2 :: 50002AC00064146C|2FF70002AC012204
...
3PARMigratedLunMapn :: 50002AC00065146C|2FF70002AC012204