System Requirements for the HPE 3PAR StoreServ / Primera / HPE Alletra 9000 Series / HPE GreenLake for Block Storage Array

Before you configure your storage array, verify that your system meets the following requirements.

Licenses

Install the following licenses.

Array

Snapshot Type

License

HPE 3PAR StoreServ

  • Snapshot

Virtual Copy

  • Clone

Virtual Copy

Install the Thin Provisioning (4096G) license for the Thin Provisioning option for cloning

HPE Primera

  • Snapshot

  • Clone

Virtual Copy

HPE Alletra 9000 Series

  • Snapshot

  • Clone

Virtual Copy

HPE GreenLake for Block

  • Snapshot

  • Clone

Virtual Copy

Version and Firmware

Ensure that you are using compatible versions and firmware.

Array

Version and Firmware

HPE 3PAR StoreServ models

  • 3.3.2.159(MU1)

  • 3.3.1.648(MU5)

  • 3.3.1.410(MU2)+P30, P32

  • 3.3.1.269(MU1)+P08, P14, P17

  • 3.2.2.709(MU6)

  • 3.2.2.390(EMU2)

  • 3.2.2(MU4)

  • 3.2.2

  • 3.2.1(MU3)

  • 3.2.1(MU2)

  • 3.1.2(MU3)

  • 2.3.1(MU4)

    Note:

    3.3.1.460 (MU3)+P49,P50, 3.2.2, and 3.1.2(MU1) do not support clone operations.

    Not supported with 3.1.3 (MU1), 3.1.1(MU3), 3.1.1 (MU2), 3.1.1 (MU1) + Patch 10, and 3.1.1.342

    In version 3.3.1 GA and later versions, because of a 3par limitation, aged snapshots with child snapshots might not be deleted on the array.

HPE Primera

  • 4.6.1

  • 4.5.15.9

  • 4.5.7.8**

  • 4.4.1.7

  • 4.3.3.2

  • 4.2.1

  • 4.0.1.3+1 (snapshot only)

Note

  • If you have upgraded to HPE Primera 4.6.1 version, ensure to set the SMIS Server Port to 5989 and enable Use secure connection to SMIS Server snapshot configurations. For more information, see snapshot configuration properties.

  • Versions 4.5.4 and 4.5.3 are not supported.

HPE Alletra 9000 Series

  • 9.6.1

  • 9.5.21

  • 9.5.18

  • 9.5.15

  • 9.5.7**

  • 9.3.3

Note

  • If you have upgraded to HPE Alletra 9000 Series 9.6.1 version, ensure to set the SMIS Server Port to 5989 and enable Use secure connection to SMIS Server snapshot configurations. For more information, see snapshot configuration properties.

  • Versions 4.5.4 and 4.5.3 are not supported.

HPE GreenLake for Block

  • 10.4.0**

  • 10.3.0

  • 10.2.0*

*Supports only Linux and VMWare systems with iSCSI protocol.

**Replication for this array version is not supported by Commvault due to the behavioral changes done by HPE in virtual volume sets and RCG.

**Replication for this version of array is pending validation by Commvault.

Protocols

Ensure that at least one of the following protocols is available.

Array

Protocol

HPE 3PAR StoreServ

  • Fibre Channel

  • iSCSI

HPE Primera

  • Fibre Channel

  • iSCSI

HPE Alletra 9000 Series

  • Fibre Channel

  • iSCSI (firmware versions 9.5.15 and above)

HPE GreenLake for Block

  • Fibre Channel

  • iSCSI

For the iSCSI protocol, on the client and proxy computers, configure the iSCSI initiator to access the storage array.

Software

Install the following software components.

Array

Required Software

HPE 3PAR StoreServ

None

HPE Primera

None

HPE Alletra 9000 Series

None

HPE GreenLake for Block

None

Ports

For snap-based operations, open port 5989 for HTTPS and port 5988 for HTTP between the CommServe computer and the storage array and between the MediaAgent and the storage array.

×

Loading...